Below, Baikong Intelligence summarizes several common issues that customers encounter when using DC brushless barrier gates:
Problem 1: The lifting rod is not vertical and the lowering rod is not horizontal
Solution: Loosen the fixed motor shaft screw while the pole is in the raised state and push the pole straight; Fixed screws.
Question 2: The pole landing motor is still running
Solution: The chassis is crooked; The ground is uneven; Release the position of the spindle adjustment rod clamp
Question 3: Power off of the controller when the barrier gate is raised and lowered in place
Solution: Insufficient power supply voltage; Motherboard damaged
Problem 4: Remote control malfunction; Remote control distance is close
Solution: The remote control battery is low; There is signal interference or receiver damage between the remote control and receiver
Question 5: The barrier gate shakes when it rises and falls in place
Solution: Check if the spring tension is balanced or if the motherboard increases the deceleration angle
Problem 6: The motor is running but the pole is unresponsive
Solution: The connection between the motor and the gearbox is damaged or the spindle screw is loose
Question 7: The barrier gate rod falls halfway and stops running
Solution: Check the spring ratio and rod drop speed
Question 8: The radar keeps detecting the pole
Solution: Tilt the radar or adjust the installation position
Question 9: The ground sensing coil keeps triggering
Solution: Vehicle inspection device malfunction or coil damage; There are a large amount of metals in the area; Wiring issues.
Question 10: The pole falls into place; The motor has been running slowly and repeatedly over short distances
Solution: Insufficient motor travel; The lock is not in place; Increase the motor stroke.