error code solution
ERR0 When clearing the remote control and restoring factory settings, it is necessary to set the correct confirmation value. If the confirmation value is incorrect, an Err0 error will be prompted.
ERR2 Warning of high brake recoil voltage, usually caused by poor spring matching and excessive speed. It can be solved by balancing the spring with the rod and reducing the operating speed. You can also increase it; P-66 setting value increases trigger threshold.
ERR3 Possible reasons for blocked rotation of the lifting rod: broken barrier spring, too low lifting speed, and too low lifting end speed. You can increase the lifting speed and lifting end speed.
ERR4 Possible reasons for blocked rotation of the falling rod include: too tight gate spring, not hanging gate rod, low speed of falling rod or end speed of falling rod. Check if the spring is too tight, if the barrier gate is attached, and increase the speed of lowering or ending the lowering.
ERR5 Lifting timeout, the reason is that the lifting time exceeds; 15 seconds. Can increase the lifting speed and lifting end speed.
ERR6 The reason for the rod falling timeout is that the rod falling time exceeds; 15 seconds. Can increase the speed of rod drop and the end speed of rod drop.
ERR7 Wrong selection of motor type, can be done through; Change P-10 to the correct type.
ERR9 During the lifting process, situations such as spring breakage may cause the motor to reverse;.
Reproduction without permission is prohibited:byekey automaticon » Common error codes and solutions for barrier gate control
Share to
0 NICE
Prev page
Next page

COMMENT (0)

CONTACT US

166-2090-1157

CopyCopied

+85244665600

CopyCopied
byekey@126.comCopyCopied
WECHAT
166-2090-1157COPYCOPIED
contact-img
WHATSAPP
+85244665600COPYCOPIED
contact-img
Email